Line Interactive Sine Wave UPS System 3kVA SNMP 2U Rack Tower USB RS232 EPO LCD Extended Runtime 120V

SmartPro 3kVA 2250W Line Interactive Sine Wave UPS, Extended-run & SNMPWEBCARD options, 2U Rack/Tower, LCD, USB, RS232, EPO, 120V

Model Number: SMART3000RM2U


  • 3kVA / 3000VA / 2250W line interactive 2U rack/tower UPS, Sine Wave
  • 120V output, Corrects brownouts and overvoltages from 83V to 145V
  • 0.75 Power Factor, Interactive LCD interface
  • Extended runtime options up to 1600W
  • 4 post compatible mounting accessories
  • 98% line-mode efficiency, 2 switched load banks
  • USB, RS232, EPO and slot for SNMPWEBCARD option
  • 120V NEMA L5-30P input, 8 NEMA 5-15/20R & 1 L5-30R outlets
  • This product is ENERGY STAR qualified for its ability to save customers money while helping to protect the environment

Tripp Lite SmartPro Line Interactive UPS with enhanced LCD interface offers network-grade power protection for critical server, network and telecommunications equipment. Line Interactive Uninterruptible Power Supply (UPS) with built-in Auto-Voltage Regulation (AVR) actively corrects brownouts and overvoltages back to usable levels while maintaining a full battery charge in case of power failure. Tripp Lite's unique configuration excels in exceptionally poor-power environments with two separate levels of voltage boost to correct both slight undervoltages and severe brownout conditions. Interactive LCD interface reports UPS operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options. Super-fast switchover from line to battery power occurs within milliseconds to maintain operation of connected equipment without interruption or reboot. 98% line-mode efficiency offers reduced heat emissions and operating costs. Network management interfaces support communications via USB, RS-232 and optional SNMPWEBCARD network interface. HID-compliant USB port enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Network communications ports enable detailed monitoring of equipment load levels, self-test data and utility power conditions. Includes PowerAlert monitoring software and complete cabling. Switched output load banks enable scheduled and real-time remote reboot and load shedding of select outlets. Emergency Power Off (EPO) interface. LCD display panel easily rotates for viewing in rackmount or tower configurations. Audible alarm with push-button momentary alarm-cancel and silent-mode configuration options. Programmable self-test. Field-replaceable, hot-swappable battery modules.

Key Features

  • Tripp Lite SMART3000RM2U line interactive 2U rack/tower UPS with 3000VA / 3kVA capacity (1600W maximum load with external battery packs)
  • Line interactive UPS with Automatic Voltage Regulation (AVR) corrects brownouts and overvoltages from 83 to 145V
  • NEMA L5-30P input plug; 8 NEMA 5-15/20R and 1 L5-30R output receptacles, Two independently switchable output load banks
  • Maintains uninterrupted operation of connected networking equipment during blackouts, surges, brownouts and overvoltages
  • High 98% efficiency rating in line-power mode offers reduced power consumption and BTU emisssions
  • Internal batteries offer 10 minutes at 50% load (1125W) and 3.5 minutes at 100% load (2250W)
  • Extended runtime is available with optional BP48V24-2U (limit 1), BP48V60RT-3U (multi-pack compatible) and BP48V27-2US (multi-pack compatible) external battery packs (max output de-rates to 1600 watts with external batteries)
  • External battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
  • Hot-swappable, user-replaceable internal batteries and external battery packs can be replaced with no disruption to connected equipment
  • Front panel LCD monitoring screen with MODE and ENTER buttons reports operating mode with 5-bar battery charge graphic, plus 7 selectable screens of detailed UPS and site power information
  • LCD interface also supports a number of advanced user setup and operating preferences
  • Ships with 4 post rackmount installation hardware; Optional 2POSTRMKITWM enables 2 post rackmount/wallmount installation; Optional 2-9USTAND enables tower placement
  • Built-in USB, RS-232 and optional SNMPWEBCARD accessory monitoring options
  • HID-compliant USB port enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
  • Included PowerAlert UPS monitoring software; Built-in Emergency Power Off (EPO) interface with cable

Package Includes

  • SMART3000RM2U UPS System
  • PowerAlert Software with USB, Serial & EPO cabling
  • 4-post rackmount installation kit
  • Instruction manual

OUTPUT

Output Capacity Details Output capacity is reduced to 1600 watts in all external battery pack configurations
Output Volt Amp Capacity (VA) 3000
Output kVA Capacity (kVA) 3
Output Watt Capacity (Watts) 2250
Output kW Capacity (kW) 2.25
Power Factor 0.75
Nominal Output Voltage(s) Supported 120V
Frequency Compatibility 60 Hz
Output Voltage Regulation (Line Mode) -14%, +6%
Output Voltage Regulation (Battery Mode) +/- 5%
UPS Output Receptacles 8 5-15/20R outlet(s); 1 L5-30R outlet(s)
Output Receptacles Two switchable single-outlet load banks
Output Circuit Breakers Two 20A output breakers protect 4 5-15/20R outlets each
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave

INPUT

Rated input current (Maximum Load) 24A
Nominal Input Voltage(s) Supported 120V AC
UPS Input Connection Type L5-30P
UPS Input Cord Length (ft.) 10
UPS Input Cord Length (m) 3
Recommended Electrical Service 30A 120V
Input Phase Single-Phase

BATTERY

Full Load Runtime (min.) 3.5 min. (2250w)
Half Load Runtime (min.) 10 min. (1125w)
Expandable Battery Runtime Extended runtime supported via optional external battery packs
External Battery Pack Compatibility BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible)
DC System Voltage (VDC) 48
Battery Recharge Rate (Included Batteries) Less than 4.5 hours from 10% to 90%
Internal UPS Replacement Battery Cartridge RBC94-2U
Battery Access Front panel battery access door
Battery Replacement Description Hot-swappable, user replaceable batteries

VOLTAGE REGULATION

Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145
Overvoltage Correction Input voltages between 127 and 145 are reduced by 12%
Undervoltage Correction Input voltages between 108 and 96 are boosted by 12%
Severe Undervoltage Correction Input voltages between 83 and 95 are boosted by 24%

LEDS ALARMS & SWITCHES

Front Panel LCD Display Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
Audible Alarm Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
Alarm Cancel Operation Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
Switches 3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions

SURGE / NOISE SUPPRESSION

UPS AC Suppression Joule Rating 570
UPS AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes

PHYSICAL

Included Mounting Accessory Description 4 post rackmount installation accessories included
Installation Form Factors Supported with Optional Accessories 2 post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND); 2-4 post front rail rackmount (UPSHDEARKIT)
Primary Form Factor Rackmount
UPS Power Module Dimensions (hwd, in.) 3.5 x 17.5 x 19.5
UPS Power Module Dimensions (hwd, cm) 8.9 x 44.4 x 49.5
Rack Height 2U
Secondary Form Factor Tower (requires 2-9USTAND )
UPS Power Module Weight (lbs.) 62.8
UPS Power Module Weight (kg) 28.5
UPS Shipping Dimensions (hwd / in.) 7.9 x 21.7 x 24.2
UPS Shipping Dimensions (hwd / cm) 20.1 x 61.5 x 62
Shipping Weight (lbs.) 73.8
Shipping Weight (kg) 33.5
Cooling Method Fan
UPS Housing Material Steel

ENVIRONMENTAL

Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 189
AC Mode Efficiency Rating (100% Load) 98%
Operating Elevation (ft.) 0-3000m / 0-10,000 ft.
Audible Noise 45 dBA max front side 1m

COMMUNICATIONS

Communications Interface USB (HID enabled); DB9 Serial; Slot for SNMP/Web interface
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions
PowerAlert Software Included
Communications Cable USB and DB9 cabling included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
Network UPS Tools Compatibility NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite

LINE / BATTERY TRANSFER

Transfer Time 5 milliseconds (AC to battery); 1 millisecond (battery to AC)
Low Voltage Transfer to Battery Power (Setpoint) 83
High Voltage Transfer to Battery Power (Setpoint) 145

SPECIAL FEATURES

Grounding Lug Includes back panel grounding lug
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Hot swappable batteries
Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS; Individually controllable load banks

CERTIFICATIONS

UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances); ENERGY STAR Qualified

WARRANTY

Product Warranty Period (Worldwide) 2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty.
Connected Equipment Insurance (U.S., Canada & Puerto Rico) $250,000 Ultimate Lifetime Insurance

† Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. See a list of Tripp Lite's testing agencies.

SMART3000RM2U 4.8 5 4 4
Happy Owner I use this on my entertainment system, and am quite satisfied; as this is the second unit I have purchased for this purpose. My first unit quit charging the batteries after 6 years of faithful service. Tripplite won't provide prints, being handy with an iron, I'm sure I could repair my old one....but that's another story. I get numerous power-bumps or voltage fluctuations monthly and have never experienced an issue with either TV or multiple DVR's & HTPC's crashing. I have to believe that this has helped keep my 10 year old electronics from ending-up in a scrap heap. Only minute complaint would be the minimal run-time with the default battery's supplied. Although, if everything is running during an outage, I still have a good 7 minutes to get it all shut down. September 5, 2013
Excellent bang for the buck!! These are the best UPS and power regulators on the market. I use 10 of these for website backup servers, and I use them in my studio. Pure power is good... April 20, 2013
have 4 total, 2 in each rack for RPS. works good and has not failed during generator testing. like a option for hot swap of batteries. would like the option to monitor via URL March 5, 2013
Little Engine that Could We currently use this box to power several network switches and also servers. We always used APC in the past but kept having issues with batteries. We have had these for 3 years and so far no issues. We haven't seen much loss of up time due to battery decay. I would recommend this ups for anybody that is looking for a cost effective solution for power outages and power conditioning. October 29, 2012
1-4 of 4
(8 Questions : 15 Answers)

Product Q&A

Ask your questions. Share your answers.

 
 
« Back
 
 
Has staff answer
 
3 answers

SMART3000RM2U / L-530 to L-520 Input plug

Can the input plug be changed from an L-530 to an L-520?
3 years ago
Customer avatar
by
Read all my Q&A
 
Please wait while more information about davides is loaded.
Additional information about davides could not be loaded.
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers

Answer: 
No, the SMART3000RM2U is a 30 amp UPS, thereby needing a 30 amp connection (L5-30)
1 year, 6 months ago
Customer avatar
by
Read all my Q&A
 
Please wait while more information about nightdiver is loaded.
Additional information about nightdiver could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Answer: 
according to the electrical code no. but as long as you have a 30 amp breaker feeding the l5-20 it should be ok.
2 years ago
Customer avatar
by
Anonymous
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Answer: 
Thanks for you interest in our UPS line of products. Please note that there should be no modifications made to the factory installed plugs. This may void your warranty as well as violate applicable electrical codes.

As the SMART3000RM2U has a 24A rated input current (at max. load), it utilizes a properly sized NEMA L5-30P AC input plug. The recommended site service rating is: 30A 120V.
3 years ago
Customer avatar
by
Read all my Q&A
 
Please wait while more information about TrippHelp is loaded.
Additional information about TrippHelp could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
1 year, 11 months ago
Customer avatar
by
Anonymous
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers

Answer: 
Yes, if the UPS has "interactive sine wave" it means the technology used allows for "pure sine wave" output of power.
1 year, 6 months ago
Customer avatar
by
Read all my Q&A
 
Please wait while more information about nightdiver is loaded.
Additional information about nightdiver could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Answer: 
We appreciate your interest in our UPS line of products. Please note that the references to "Line-Interactive" describes the voltage regulation topology of the UPS, and the "Sine-Wave" describes the output waveform, in this case a Pure Sine Wave.

If you'd like to discuss your application and how you’ll use this product further, our Chicago-based team of tech support experts is available to work with you at your convenience online and via phone or fax:

Online Pre Sales Support
Phone: 773.869.1234
Fax: 773.869.1177

Thanks again for your interest in Tripp Lite. Your satisfaction is our top priority
1 year, 10 months ago
Customer avatar
by
Read all my Q&A
 
Please wait while more information about TrippHelp is loaded.
Additional information about TrippHelp could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Answer: 
We appreciate your interest in our UPS line of products. Please note that references to "Line-Interactive" describe the voltage regulation topology of the UPS, and "Sine Wave" describes the output waveform, in this case a Pure Sine Wave.

If you'd like to discuss your application and how you’ll use this product further, our Chicago-based team of tech support experts is available to work with you at your convenience online and via phone or fax:

Online Pre Sales Support
Phone: 773.869.1234
Fax: 773.869.1177

Thanks again for your interest in Tripp Lite. Your satisfaction is our top priority
1 year, 10 months ago
Customer avatar
by
Read all my Q&A
 
Please wait while more information about TrippHelp is loaded.
Additional information about TrippHelp could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
2 years, 2 months ago
Customer avatar
by
Read all my Q&A
 
Please wait while more information about tdyer77 is loaded.
Additional information about tdyer77 could not be loaded.
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers

Answer: 
no
2 years ago
Customer avatar
by
Anonymous
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Answer: 
We appreciate your interest in our UPS line of products. Please note that the SMART3000RM2U operates via a 120V input voltage.

If you'd like to discuss your 208V application and how you’ll use this product further, our Chicago-based team of tech support experts is available to work with you at your convenience online and via phone or fax:

Online Pre Sales Support
Phone: 773.869.1234
Fax: 773.869.1177

Thanks again for your interest in Tripp Lite. Your satisfaction is our top priority
2 years, 2 months ago
Customer avatar
by
Read all my Q&A
 
Please wait while more information about TrippHelp is loaded.
Additional information about TrippHelp could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
I currently have one UPS in place and would like to use the AC output on the SMART3000RM2U to keep from installing a new AC plug. I can't determine if this output is a backup or just surge protected.
1 year, 8 months ago
Customer avatar
by
jimdata
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers

Answer: 
It is surge protected, and allows another UPS to be plugged in. If you have the SMART3000RM2U plugged into this outlet, you do not need the backup from the original UPS...
1 year, 6 months ago
Customer avatar
by
Read all my Q&A
 
Please wait while more information about nightdiver is loaded.
Additional information about nightdiver could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Answer: 
We appreciate your online response to the SMART3000RM2U you've recently purchased. Please note that as the L5-30R site receptacle you're utilizing to power the existing UPS is only rated for a 30A capacity, pulling current that surpasses this rating then will trip your upstream breaker. That said, connecting a UPS to the output of a UPS is not reccommended.

Our Chicago-based team of tech support experts is available to work with you at your convenience online and via phone or fax:

Online Tech Support
Phone: 773.869.1234
Fax: 773.869.1177

Please have the unit(s) serial numbers available for quick reference when calling.
1 year, 8 months ago
Customer avatar
by
Read all my Q&A
 
Please wait while more information about TrippHelp is loaded.
Additional information about TrippHelp could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
St. Lucia Air and Sea Ports Authority bought two Smart UPS.
Model Number: SMART3000RM2U
Serial Numbers: 9523ALCSM522600159 and 9523ALCSM522600149.
They were in storage for more than three years.
I applied power to them but neither of them came on.
The internal batteries are dead.
Can the UPS turn on without the internal batteries?
I am a electronics technician but I have have had no training on TRIPP-LITE UPS.
1 year, 7 months ago
Customer avatar
by
Andre Klien
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers

Answer: 
Hi Andre,

No, they cannot turn on without the internal batteries. The easiest thing to do is to replace just the batteries... That will give you a new power supply (and a good one at that) at a fraction of the cost of a new unit.
1 year, 6 months ago
Customer avatar
by
Read all my Q&A
 
Please wait while more information about nightdiver is loaded.
Additional information about nightdiver could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Answer: 
We appreciate your online response to the SMART3000RM2U units in question. Please note that each UPS requires that an appropriate DC battery voltage be present in order to energize. For future reference, we strongly suggest that batteries be charged once every three months if stored for prolonged periods to prevent permanent loss of capacity.

Please contact our Chicago-based team of tech support experts directly in order to discuss your battery replacment cartridge options at your convenience, online and via phone or fax:

Online Tech Support
Phone: 773.869.1234
Fax: 773.869.1177

Please have the unit(s) serial numbers available for quick reference when calling.
1 year, 7 months ago
Customer avatar
by
Read all my Q&A
 
Please wait while more information about TrippHelp is loaded.
Additional information about TrippHelp could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
2 next>>
2 next>>

PowerAlert

Free Power Management Software for your SMART3000RM2U

learn more

Runtime at Full Load

3.5 min. (2250w)

Runtime at Half Load

10 min. (1125w)

see complete runtime chart

Do you own a SMART3000RM2U?

Get all your support resources in one place.

go to model support
RBC54 replacement UPS battery Does your UPS need a new battery?

The SMART3000RM2U has multiple battery configurations. Our easy-to-use Battery Finder can help..

go to Battery Finder

Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.

How can we improve the information on this page? Is an important specification missing? Did you spot an error? Please let us know how we can make this information more useful to you.