On Line Double Conversion UPS System 3kVA 3U Rack Tower 208V 240V NEMA Outlets

SmartOnline 200-240V 3kVA 2.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack/Tower, DB9 Serial

Model Number: SU3000RTXL3UHV


  • 3000VA / 3kVA / 2400 watt on-line double-conversion 3U rack/tower UPS
  • 208/240V +/-2% output at 50/60Hz
  • Expandable runtime, Hot-swappable battery modules
  • RS232 port; support for SNMP/WEB card options
  • Front panel status LEDs with detailed load and battery metering
  • NEMA L6-20P input; 6-15/20R & L6-20R outlets
(4 Reviews)
Read all 4 reviews  |  Write a Review

3000VA / 3kVA on-line, double-conversion UPS system for critical server, network and telecommunications equipment. 3U rackmount form factor with an installed depth of 20 inches (50.8cm). Expandable battery runtime with optional external battery packs BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-pack compatible). Full time sine wave 200/208/220/240V AC output with +/-2% voltage regulation. Online, double-conversion Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 130V and overvoltages to 275V. NEMA L6-20P input plug. NEMA 6-15/20R & L6-20R output receptacles. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces support simultaneous communications via DB9 serial port and SNMPWEBCARD slot. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact closure monitoring ability. Supports simultaneous detailed monitoring of equipment load levels, self-test data and mains power conditions via all network interfaces. Includes PowerAlert monitoring software and complete cabling. Integrated two bank PDU switching supports load shedding and remote-reboot of connected equipment. Multi-stage metered current monitoring and battery charge status LEDs. Mains power and voltage regulation LEDs. Audible Alarm. Self-test. Fault-tolerant auto-bypass mode. 4 post rackmount accessories included; 2-9USTAND tower kit and 2POSTRMKITWM 2-post rackmount accessories available. Field replaceable, hot swappable internal batteries and external battery packs. Attractive all-black UPS design. $250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only).

Key Features

  • True on-line, double conversion UPS provides pure, sine wave AC output at all times
  • Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
  • Removes harmonic distortion, electrical impulses, frequency variations and other hard to solve power problems
  • Accepts input voltages between 160 and 275 (130 to 275 at loads under 70%), regulating output to selectable 200/208/220/240V +/-2%
  • 3000VA/2400 watt power capacity with 8 total outlets (6 NEMA6-15/20R & 2 NEMAL6-20R)
  • Standard internal battery set provides 14 minutes runtime at half load
  • Expandable runtime with external battery packs BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-pack compatible)
  • Innovative design makes unit adaptable for rackmount, tower, or stacking applications
  • Uses only 3 rack spaces (3U) in standard 19 inch rack
  • DB9 serial port for network interface; SNMP compatible
  • Slot for optional SNMP/web card (part# SNMPWEBCARD)
  • PowerAlert unattended shutdown software and 6 ft. network cable included
  • Compatible with Tripp Lite's Watchdog Service Monitoring/Reboot Software
  • Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
  • Diagnostic LEDs
  • Battery replacement door
  • Mounting hardware included for 4 post rack enclosures, tower placement supported with optional 2-9USTAND accessory, 2 post telecom rack compatible with optional 2POSTRMKITHD accessory
  • $250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only)

Typical Applications

  • Distributed Server Rooms
  • Network Closets
  • Small Business Networks
  • Voice over IP (VoIP) Phone Systems

Package Includes

  • SU3000RTXL3UHV Rack-Tower UPS System
  • PowerAlert Software and cabling
  • Mounting hardware for 4 post rackmount enclosures
  • Warranty information
  • Instruction manual

OUTPUT

Output Capacity Details Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds
Output Volt Amp Capacity (VA) 3000
Output kVA Capacity (kVA) 3
Output Watt Capacity (Watts) 2400
Output kW Capacity (kW) 2.4
Power Factor 0.8
Crest Factor 3:1
Nominal Output Voltage(s) Supported 200V; 208V; 220V; 240V
Nominal Voltage Details 208V default
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start
Output Voltage Regulation (Line Mode) +/- 2%
Output Voltage Regulation (Battery Mode) +/- 2%
Output Receptacles (6) 6-15/20R; (2) L6-20R
Load Management Receptacles Two switchable 6-15/20R load banks (bank 1 - two outlets, bank 2 - four outlets)
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Onda sinusoidal pura

INPUT

Rated input current (Maximum Load) 14.9A (200V), 14.3A (208V), 13.1A (220V), 12.1A (240V)
Nominal Input Voltage(s) Supported 200V CA; 208V CA; 220V CA; 240V CA
UPS Input Connection Type L6-20P
Input Circuit Breakers 25A double pole
UPS Input Cord Length (ft.) 10
UPS Input Cord Length (m) 3
Recommended Electrical Service 20A
Input Phase Monofásicos

BATTERY

Full Load Runtime (min.) 5 min. (2400w)
Half Load Runtime (min.) 14 min. (1200w)
Expandable Battery Runtime Supports extended runtime with optional external battery packs
External Battery Pack Compatibility BP72V15-2U (límite 1); BP72V28RT-3U (compatible con multi-paquete); BP72V18-2US (compatible con multi-paquete)
DC System Voltage (VDC) 72
Battery Recharge Rate (Included Batteries) Less than 6 hours from 10% to 80% (typical, full load discharge)
Internal UPS Replacement Battery Cartridge RBC96-3U
Battery Access Front panel battery access door
Battery Replacement Description Hot-swappable, user replaceable batteries

VOLTAGE REGULATION

Voltage Regulation Description Online, double-conversion power conditioning
Overvoltage Correction Maintains output during overvoltages to 275
Undervoltage Correction Maintains output during undervoltages to 160V AC
Severe Undervoltage Correction At load levels less than 70%, UPS maintains output during undervoltages to 130V AC

LEDS ALARMS & SWITCHES

LED Indicators 14 LEDs indicate line power, online mode, bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats
Audible Alarm Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch
Switches 2 switches control off/on power status and alarm-cancel/self-test operation

SURGE / NOISE SUPPRESSION

UPS AC Suppression Joule Rating 2670
UPS AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression

PHYSICAL

Included Mounting Accessory Description Includes 4 post rackmount installation accessories
Installation Form Factors Supported with Optional Accessories Rack con 2 postes (2POSTRMKITHD); Torre (2-9USTAND)
Primary Form Factor Rack
UPS Power Module Dimensions (hwd, in.) 5.2 x 17.3 x 19.8
UPS Power Module Dimensions (hwd, cm) 13.2 x 43.9 x 50.3
Rack Height (U Spaces) 3
UPS Power Module Weight (lbs.) 74.9
UPS Power Module Weight (kg) 34
UPS Shipping Dimensions (hwd / in.) 13.3 x 23.8 x 25.7
UPS Shipping Dimensions (hwd / cm) 33.8 x 60.5 x 65.3
Shipping Weight (lbs.) 90.3
Shipping Weight (kg) 41
Cooling Method Fan
UPS Housing Material Steel

ENVIRONMENTAL

Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 1112.7
Battery Mode BTU / Hr. (Full Load) 1219.3
AC Mode Efficiency Rating (100% Load) 88%

COMMUNICATIONS

Communications Interface DB9 Serial; Cierre de contacto; Ranura para interfaz SNMP/Web
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications
Communications Cable DB9 cable included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications

LINE / BATTERY TRANSFER

Transfer Time No transfer time (0 ms.) in online, double-conversion mode
Low Voltage Transfer to Battery Power (Setpoint) 160V (100% load), 130V ( <70% load)
High Voltage Transfer to Battery Power (Setpoint) 275

SPECIAL FEATURES

Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Derivación de inversor automático; Baterías de cambio en operación
Green Energy-Saving Features Bancos de carga controlables individualmente

CERTIFICATIONS

UPS Certifications Probado conforme a UL1778 (EE. UU.); Probado conforme a CSA (Canadá); Probado conforme a NOM (México); Cumple con FCC Parte 15 Clase A (EMI)

WARRANTY

Product Warranty Period (Worldwide) garantía limitada de 2 años
Connected Equipment Insurance (U.S., Canada & Puerto Rico) 250,000 dólares de seguro máximo de por vida

† Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. See a list of Tripp Lite's testing agencies.

REVIEW SNAPSHOT®

by PowerReviews
Tripp LiteSmartOnline 3kVA On-Line Double-Conversion UPS 3U Rack/Tower 208/240V NEMA outlets
 
5.0

(based on 4 reviews)

Ratings Distribution

  • 5 Stars

     

    (4)

  • 4 Stars

     

    (0)

  • 3 Stars

     

    (0)

  • 2 Stars

     

    (0)

  • 1 Stars

     

    (0)

75%

of respondents would recommend this to a friend.

Reviewed by 4 customers

Sort by

Displaying reviews 1-4

Back to top

 
5.0

Great Product

By 

from Undisclosed

Comments about Tripp Lite SmartOnline 3kVA On-Line Double-Conversion UPS 3U Rack/Tower 208/240V NEMA outlets:

Used it for years, not one issue! Truly a plug and play solution for a SMB.

Comment on this review

 
5.0

Reliable

By 

from Undisclosed

Comments about Tripp Lite SmartOnline 3kVA On-Line Double-Conversion UPS 3U Rack/Tower 208/240V NEMA outlets:

Was very simply to wire in and is even more reliable when power goes out. The best investment you will ever make!jsmith

Comment on this review

(1 of 1 customers found this review helpful)

 
5.0

240V on-line UPS

By 

from Undisclosed

Comments about Tripp Lite SmartOnline 3kVA On-Line Double-Conversion UPS 3U Rack/Tower 208/240V NEMA outlets:

This UPS is used outdoors in a covered shed to protect an expensive DC variable voltage fertilizer injector which requires true and reliable 240V single stage power and a copper ion injector system for a commercial orchid nursery in south Florida. Our summers are 9 months long - hot and steamy-humid. I had to protect our equipment from the frequent lightning strikes along with voltage drops and surges from FPL. I built a stand to get the UPS up near the polycarbonate roof, but it is still located above 2 fertilizer tanks holding concentrated fertilizer (salts) and a potassium hydroxide tank. I provide constant airflow using a cheap plastic fan which may prevent some overheating problems. There is some corrosion (humidity, salts, etc) but the unit keeps operating as it should.

Comment on this review

 
5.0

Simple and easy

By 

from Undisclosed

Comments about Tripp Lite SmartOnline 3kVA On-Line Double-Conversion UPS 3U Rack/Tower 208/240V NEMA outlets:

Very simple and easy to rack mount, and get up and running.

Comment on this review

Displaying reviews 1-4

Back to top

Product Warranty

This product has a garantía limitada de 2 años. Get more information

Insurance Coverage

This product includes a 250,000 dólares de seguro máximo de por vida for connected equipment. Click for details

Software & Downloads

More Support Resources for SU3000RTXL3UHV

PowerAlert

Free Power Management Software for your SU3000RTXL3UHV

learn more

Runtime at Full Load

5 min. (2400w)

Runtime at Half Load

14 min. (1200w)

see complete runtime chart

Do you own a SU3000RTXL3UHV?

Get all your support resources in one place.

go to model support
RBC96-3U replacement UPS battery Does your UPS need a new battery?

Get it here! Your SU3000RTXL3UHV requires 1 RBC96-3U battery.

product page

Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.

How can we improve the information on this page? Is an important specification missing? Did you spot an error? Please let us know how we can make this information more useful to you.