Possible Product/Country Incompatibility

This product may be incompatible with your voltage or frequency, or it may be designed to comply with the standards or usage in another country. [MP0042]

High-capacity 3.8kW PDU with ATS provides remote power monitoring and enables redundant power for non-redundant hardware. Digital display and Ethernet interface allow load monitoring to prevent overloads that cause downtime.

  • Two IEC309 16A Blue (2P+E) inputs with 10-ft. (3.05 m) cords
  • IEC309 16A Blue outlet (2P+E) for connecting device or 0U PDU
  • Automatic transfer switching within 1-5 ms
  • Built-in LX Platform network interface for remote access
  • Digital display with LEDs for real-time status monitoring
  • 2-year limited warranty

Overview

The PDUMNH16HVAT 3.8kW Single-Phase 200-240V Monitored Automatic Transfer Switch / ATS PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and has an IEC309 16A Blue outlet for connecting a single device or a 0U 230V vertical PDU with IEC309 16A Blue plug.
Dual 10-ft. (3.05 m) input cords with IEC309 16A Blue plugs connect to separate primary and secondary single-phase power sources, including out-of-phase sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds if the primary source fails or becomes unstable to ensure connected equipment remains powered.
Built-in LX Platform network management interface. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separate) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. Digital display with LEDs indicates power availability, voltage, input status for both power sources, output load and power factor, as well as temperature and humidity conditions with optional ENVIROSENSE2 module (sold separate).

Features

Primary and Secondary Inputs for Power Redundancy
  • Offers remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations
  • IEC309 16A Blue (2P+E) inputs with 10-ft. (3.05 m) cords connect to separate primary and secondary single-phase power sources
  • Fault-tolerant, hot-swappable UPS protection when used with single UPS; fully redundant UPS protection when each cord is connected to a separate UPS
Built-In IEC309 16A Blue Outlet
  • Powers a single device or indirectly powers equipment through a 0U 230V PDU with IEC309 16A Blue input (sold separately)
Automatic Transfer Switching
  • Dynamic solid-state (TRIAC) automatic transfer switching
  • Switches to secondary power source if primary source fails or becomes unstable
  • 1-5 ms transfer time ensures uninterrupted operation of connected equipment
  • Built-in processor monitors power sources and prevents switching if secondary source is unavailable or of lower quality than primary source
Multifunction Digital Display with LEDs
  • Reports input status for primary and secondary power sources, power availability, line voltage, frequency, amps, kilowatts and power factor
Advanced Network Monitoring
  • LX Platform interface allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSH
  • Real-time load/current data with billing-grade accuracy (+/- 1 percent)
  • Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities
Broad Communications Compatibility
  • HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
  • 10/100 Mbps auto-sensing for communication with 10/100 Base-T networks
Mounts Horizontally in 1U of Rack Space
  • Compatible with EIA-standard 19 in. 4-post racks and rack enclosures
  • Optional PDU4PKIT rail kit (sold separately) adds rear mounting support

Package Includes

    • PDUMNH16HVAT 3.8kW Single-Phase 200-240V ATS/Monitored PDU
    • Rack-mounting brackets
    • Owner’s manual
    RoHS compliant

    Specifications

    OVERVIEW
    UPC Code037332186560
    PDU TypeMonitored; Auto-Transfer Switch
    INPUT
    Input PhaseSingle-Phase
    PDU Input Voltage200; 208; 220; 230; 240
    Recommended Electrical ServiceTwo single-phase 16A 200-240V circuits
    Maximum Input Amps16
    Maximum Input Amps DetailsAgency de-rated to 16A continuous
    PDU Plug Type(2) IEC-309 16A BLUE (2P+E)
    Input Cord DetailsSet of two inputs connect to separate PRIMARY and SECONDARY power sources
    Input Cord Length (ft.)10
    OUTPUT
    Output Capacity Details3.8kW (240V); 3.7kW (230V); 3.5kW (220V); 3.3kW (208V); 3.2kW (200V); 16A maximum
    Frequency Compatibility50 / 60 Hz
    Output Receptacles(1) IEC309 16A BLUE (2P+E)
    Output Nominal Voltage200-240V
    USER INTERFACE, ALERTS & CONTROLS
    Front Panel LCD DisplayDigital display reports input current in amps (Source A, Source B), output kilowatts (total), input voltage (Source A, Source B), input frequency (Source A, Source B) and output power factor
    Front Panel LEDsFront panel LEDs confirm amp (A) / kilowatt (kW) / voltage (V) / frequency (Hz) and power factor (PF) reporting information; Additional set of LEDs indicate Source A and Source B inputs for preferred, available and in-use status
    SwitchesENTER and MODE switches toggle the digital display to display all reported information
    Current Measurement Accuracy (Amps)+/-1%
    Voltage Measurement Accuracy (Volts)+/-1%
    Power Measurement Accuracy (Watts)+/-1%
    PHYSICAL
    Material of ConstructionMetal
    Form Factors Supported1U rackmount
    Minimum Required Rack Depth (inches)17.5
    PDU Form FactorHorizontal (1U)
    Shipping Dimensions (hwd / in.)7.20 x 20.50 x 21.10
    Shipping Weight (lbs.)16.70
    Unit Dimensions (hwd / in.)1.720 x 16.930 x 14.000
    Unit Weight (lbs.)17.36
    ENVIRONMENTAL
    Operating Temperature Range32° to 104°F (0° to 40°C)
    Storage Temperature Range-22° to 122°F (-30° to 50°C)
    Relative Humidity5% to 95% non-condensing
    Operating Elevation0-10000 ft. (0-3000 m)
    COMMUNICATIONS
    PowerAlert SoftwareLX Platform Interface: PowerAlert Device Manager
    Communications CableMicro-USB- to-USB A configuration/console Access cable
    Network Monitoring Port  RJ45 Network port, Micro-USB Configuration port, USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules.
    Network Compatibility10 Mbps; 100 Mbps (Fast Ethernet)
    FEATURES & SPECIFICATIONS
    High Availability PDU Features  Auto-Transfer Switching
    STANDARDS & COMPLIANCE
    Product CertificationsEN 60950-1
    Product ComplianceRoHS; CE (Europe)
    WARRANTY & SUPPORT
    Product Warranty Period (Worldwide)2-year limited warranty

    Questions & Answers

    Accessories

    Power Distribution Units (PDUs)

      Model Number Description
    3.7kW Single-Phase Local Metered PDU, 208/230V Outlets (8 C13, 2 C19) IEC-309 16A Blue, 8 ft. (2.43 m) Cord, 1U Rack-Mount, TAA PDUMH16HV PDUMH16HV 3.7kW Single-Phase Local Metered PDU, 208/230V Outlets (8 C13, 2 C19) IEC-309 16A Blue, 8 ft. (2.43 m) Cord, 1U Rack-Mount, TAA
    3.7kW Single-Phase Local Metered PDU, 208/230V Outlets (32-C13, 6-C19), IEC309 16A Blue 16A, 0U Vertical PDUMV16HV PDUMV16HV 3.7kW Single-Phase Local Metered PDU, 208/230V Outlets (32-C13, 6-C19), IEC309 16A Blue 16A, 0U Vertical

    Power Cords and Adapters

      Model Number Description
    IEC 309 to C19, Heavy-Duty Extension Cord - 16A, 250V, 16 AWG, 10 ft. (3.05 m), Black P070-010 P070-010 IEC 309 to C19, Heavy-Duty Extension Cord - 16A, 250V, 16 AWG, 10 ft. (3.05 m), Black

    Environmental Sensors

      Model Number Description
    EnviroSense2 (E2) Environmental Sensor Module, Temperature E2MT E2MT EnviroSense2 (E2) Environmental Sensor Module, Temperature
    EnviroSense2 (E2) Environmental Sensor Module with Temperature and Digital Outputs E2MTDO E2MTDO EnviroSense2 (E2) Environmental Sensor Module with Temperature and Digital Outputs
    EnviroSense2 (E2) Environmental Sensor Module with Temperature, Humidity and Digital Inputs E2MTHDI E2MTHDI EnviroSense2 (E2) Environmental Sensor Module with Temperature, Humidity and Digital Inputs

    Accessories

      Model Number Description
    SmartRack Rear Support Rail Kit for Select 1U ATS PDUs Mounted in 4-Post Racks and Rack Enclosures PDU4PKIT PDU4PKIT SmartRack Rear Support Rail Kit for Select 1U ATS PDUs Mounted in 4-Post Racks and Rack Enclosures

    Services & Extended Warranties

    Extended Warranty

    Part Number Description
    WEXT1G Extended Warranty and Technical Support for Select Products – KVM, PDUs, Inverters
    WEXT2G Extended Warranty and Technical Support for Select Products – KVM Switches, PDUs, Power Inverters
    WEXT3G Extended Warranty and Technical Support for Select Products – KVM, PDUs, Power Inverters

    Need help with your purchase?
    We're always available to help with questions, including product selection, sizing, installation and product customization. Call us at +1 773-869-1776 or email cpdipresaleshelp@eaton.com.