Model Number: PDUMH30HVNET

5.8kW Single-Phase Switched PDU, 208/240V Outlets (16 C13), L6-30P Input, 12ft Cord, 2U Rack-Mount, TAA

//prodzone-tripplite.netdna-ssl.com/shared/product-images/lg/PDUMH30HVNET-FRONT-L.jpg

 
  • Switched 30A 208/240V PDU, 2U horizontal rackmount format
  • Reports voltage, frequency & load level via ethernet interface
  • Visual current meter, Reversible housing
  • NEMA L6-30P input plug with attached 12 ft. / 3.6m line cord
  • 16 switched C13 outlets with cord retention brackets
  • Temperature, humidity and contact closure monitoring options
  • Compliant with the Federal Trade Agreements Act(TAA) for GSA Schedule purchases
$63799

1398088

$53979

B0013HY9E2

$59999

7398866

$75499

PDUMH30HVNET

$59899

000826515

$56399

12-120-336

$62799

A7069115

$60854

8326363

$59999

7398866

How to Choose a PDU: Switched PDUs

Overview

Tripp Lite single phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps is continuously displayed locally via visual meter and remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip.

Features

  • 30A 208/240V Switched Power Distribution Unit / PDU with built-in web/network interface(Agency derated to 24A continuous)
  • Attached L6-30P 208/240V single phase input, 12 ft. / 3.6m input cord
  • 2U horizontal rackmount form factor
  • 16 switched c13 outlets
  • Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis
  • Enables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional loads and disabling unused outlets
  • Network interface provides PDU control and data regarding input voltage and total output load level in amps
  • Digital display continuously reports output load in amps in 3 segments(load bank 1, load bank 2, total)
  • Supports user-specified alarm notification thresholds
  • In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors
  • DHCP/Manual configuration support
  • 10/100 Mbps auto-sensing
  • Real-time clock backup maintains the time of day and date even if the PDU is unpowered
  • Tiered access privileges allow an administrator and a guest to login via web browser
  • Alert notifications via email or SNMP traps offer immediate event notification
  • Firmware upgrade ability supports future product enhancements
  • Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols
  • Fully compatible with FREE PowerAlert Network Management System / NMS Software
  • 2U horizontal rack installation supported in 2 or 4 post racks with included mounting brackets
  • Mounting brackets support wall-mount and under-counter installation in many applications
  • Included cord retention brackets
  • Compliant with the Federal Trade Agreements Act(TAA) for GSA Schedule purchases

Package Includes

  • Rackmount PDU
  • Installable 2U mounting brackets
TAA compliant
Cisco compatible
RoHS compliant

Specifications

OVERVIEW
PDU Type Switched
OUTPUT
Output Capacity Details 5.8kW (240V), 5kW (208V), 4.8kW (200V) total capacity / 30A max (Agency de-rated to 24A), 20A max per breakered outlet bank; 12A max per C13 outlet
Frequency Compatibility 50 / 60 Hz
Output Receptacles (16) C13
Output Nominal Voltage 200; 208; 240
Overload Protection Two 15A breakers protect 8 outlets each
Customized Load Management Receptacles Each outlet is individually controllable via remote interface
INPUT
PDU Input Voltage 200; 208; 240
Recommended Electrical Service 30A 208/240V
Maximum Input Amps 30
Maximum Input Amps Details Agency de-rated to 24A continuous
PDU Plug Type NEMA L6-30P
Input Cord Length (ft.) 12
Input Phase Single-Phase
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Digital display reports output amps in 3 separately metered loading segments (BANK 1: Outlets #1-8; BANK 2: Outlets #9-16; BANK 3: All outlets combined)
Front Panel LEDs 16 power availability LEDs confirm power off/on status for each built-in outlet; Two additional LEDs identify which bank the visual current meter is reporting (Bank 1, Bank 2 or Banks 1&2 combined)
Switches Pushbutton near the digital current meter advances the display of output current for Bank 1, Bank 2 and Banks 1&2 combined
PHYSICAL
Minimum Required Rack Depth (inches) 14.8
Shipping Dimensions (hwd / in.) 8 x 20.5 x 17
Shipping Weight (lbs.) 17.1
Unit Dimensions (hwd / in.) 3.5 x 17.5 x 12.5
Unit Weight (lbs.) 13.8
Material of Construction Metal
Form Factors Supported 2U rackmount. Includes mounting accessories for 4 post installation, requires optional 2POSTRMKITWM for 2 post rackmount installation)
PDU Form Factor Horizontal (1U, 2U, etc)
ENVIRONMENTAL
Storage Temperature Range 5 to 122F (-15 to 50C)
Relative Humidity 5-95% non-condensing
Operating Elevation (ft.) 0-10,000
COMMUNICATIONS
SNMP Compatibility Yes, pre-installed SNMPWEBCARD provides remote monitoring via web, telnet, and SNMP management systems. Remote management gives user ability to turn connected loads on or off individually
CERTIFICATIONS
Certifications Tested to UL 60950-1 (USA, Canada), Class A (Emissions), NOM (Mexico), RoHS compliant, TAA Compliant
WARRANTY
Product Warranty Period (Worldwide) 2-year limited warranty

Accessories

2POSTRMKITWM
2POSTRMKITWM

2-Post Rack-Mount or Wall-Mount Adapter Kit for select Rack-Mount UPS Systems

More... Prices
ENVIROSENSE
ENVIROSENSE

EnviroSense Rack Environment Sensor, Temperature, Humidity, Contact-Closure Inputs

More... Prices
SRCABLEDUCT1U
SRCABLEDUCT1U

SmartRack 1U Horizontal Cable Manager - Finger duct with cover

More... Prices
SRCABLERING1U
SRCABLERING1U

SmartRack 1U Horizontal Cable Manager - Flexible ring type

More... Prices
SRCABLERING2U
SRCABLERING2U

SmartRack 2U Horizontal Cable Manager - Flexible ring type

More... Prices
P005-002
P005-002

Heavy-Duty Power Extension Cord, 15A, 14AWG (IEC-320-C14 to IEC-320-C13), 2-ft.

More... Prices
P005-006
P005-006

Heavy-Duty Power Extension Cord, 15A, 14AWG (IEC-320-C14 to IEC-320-C13), 6-ft.

More... Prices
P005-010
P005-010

Heavy-Duty Power Extension Cord, 15A, 14AWG (IEC-320-C14 to IEC-320-C13), 10-ft.

More... Prices
P041-001-2
P041-001-2

Heavy-Duty Power Extension Cord Y Splitter Cable, 30A, 10AWG (NEMA L6-30P to 2x NEMA L6-30R), 1-ft.

More... Prices
P047-002
P047-002

Heavy-Duty Power Extension Cord, 15A, 14AWG (IEC-320-C19 to IEC-320-C14), 2-ft.

More... Prices
P047-004
P047-004

Heavy-Duty Power Extension Cord, 15A, 14AWG (IEC-320-C19 to IEC-320-C14), 4-ft.

More... Prices
P047-006
P047-006

Heavy-Duty Power Extension Cord, 15A, 14AWG (IEC-320-C19 to IEC-320-C14), 6-ft.

More... Prices
P047-010
P047-010

Heavy-Duty Power Extension Cord, 15A, 14AWG (IEC-320-C19 to IEC-320-C14), 10-ft.

More... Prices

Similar Products

Extended Warranties

WEXT1F
WEXT1F

1-Year Extended Warranty - For select Tripp Lite Products

More... Prices
WEXT2F
WEXT2F

2-Year Extended Warranty - For select Tripp Lite Products

More... Prices
WEXT3F
WEXT3F

3-Year Extended Warranty - For select Tripp Lite Products

More... Prices


Clear List